Introduction

Multiphase flow, as a transient and dynamic system subject to highly nonlinear and hierarchical multi-scale features, is prevalent in the natural environment, industrial processes and scientific research1,2,3. Representative phenomena include blood flow in blood vessels4, gas-liquid flow in post-combustion carbon capture processes5, oil-gas flow in the energy industry6, and micro-fluidic systems in biomedical research7. A critical challenge in this field is the quantitative visualization and characterization of the multiphase flow, which is vital to the fundamental study of the underlying fluid mechanics, the prediction and control of the flow response, process modeling, and the safe operation of industrial facilities8,9. Although some imaging techniques, e.g., X-ray tomography10,11,12and Magnetic Resonance Imaging (MRI)13, can be used to provide quantitative flow images, their viability is severely constrained by their limited versatility, scalability, high cost, and non-negligible radiological hazard. Electrical Tomography (ET), e.g., Electrical Capacitance Tomography (ECT) and Electrical Impedance Tomography (EIT), is considered a promising alternative technology for multiphase flow visualization and characterization14,15. It can provide an agile, noninvasive and nonradioactive way to unravel the time-varying distribution of the internal physical properties at high temporal resolution thus facilitating the study of dynamic flow behavior at different scales and under extreme conditions14,16.

Despite advances in sensors, system design, and inverse problem theory, existing ET techniques are still inadequate for quantitative imaging of multiphase flows17,18. The underlying reason is the ill-posed and ill-conditioned nature of the ET inverse problem19, which leads to inevitable inversion errors. Another issue lies in the limited availability of ground truth data of fluid phases distribution for quantitative image evaluation and validation20. This is due to the highly complex nature of multiphase flows, which systematically prevents the time-history recording of accurate flow profiles.

Emerging deep learning and data-driven methods have the potential to resolve the nonlinear ET inverse problem21,22. Several learning-based imaging models, e.g., end-to-end learning23,24, model-based deep learning25,26, and unsupervised learning27,28,研究了high-resolution ET image reconstruction. The dataset plays a central role in these learning-based imaging approaches and determines the network’s accuracy and generalization ability. Since the ground truth of multiphase flow profiles cannot be readily obtained in practice, the datasets of existing learning-based approaches are mainly constructed from static phantom data. Such static datasets are far from actual flow distributions and contain little information on dynamic flow behaviors, making learning-based models unfit to be transferred into realistic multiphase flow imaging scenarios.

We here propose a Digital Twin (DT) framework of ET to achieve quantitative imaging of multiphase flows by encapsulating dynamic 3D field-coupling simulation, model-based deep learning, and edge computing. The DT framework is summarized in Fig.1. The physical entity includes the testing section of a multiphase flow facility (Fig.1a), the ET system (Fig.1b), and the edge computer (Fig.1c). A three-dimensional Fluid-Electrostatic field Coupling Model (3D-FECM) is developed as the digital representation of the physical multiphase flow imaging system. With 3D-FECM, the dynamic behavior of the real multiphase flows can be modeled, and instantaneous virtual ET measurements can be obtained simultaneously. By conducting dynamic coupling simulations, a virtual dataset consisting of tomographic data and corresponding flow profiles is generated (Fig.1f). The framework also comprises a lightweight deep neural network (Fig.1g), i.e., Deep Back Projection (DBP) (see Methods for details), trained based on the dataset and then implemented in the edge computer for quantitative multiphase flow imaging in the physical platform.

Fig. 1: The digital twin framework of electrical tomography for quantitative multiphase flow imaging.
figure 1

aThe testing section of the multiphase flow facility. The system/feature data are captured via the sensors installed in the testing section.bThe electrical tomography system.cThe edge computer (i.e., NVIDIA Jetson Nano) implements the AI-based quantitative imaging model.dThe 3D geometrical model of the testing section and the 12-electrode tomography sensor.eSchematic of the 3D fluid-electric field-coupling simulation based on the model ind.fIllustration of the generated virtual tomographic sensing data and corresponding dynamic flow distributions within the sensing region.gThe model-based deep neural network, Deep Back Projection (DBP), for quantitative flow imaging. DBP is trained based on the dataset infand implemented inc.hThe edge computer’s output generates quantitative flow images and key parameters estimation based on the output ofb.

The DT framework provides an efficient way for ET to learn the dynamic flow features in the virtual space and enable quantitative multiphase flow imaging in the physical space. The DT framework is demonstrated on ECT and gas-liquid flow in this work but can be readily extended to other electrical tomography modalities, e.g., EIT or magnetic induction tomography, different multiphase flows, e.g., liquid-solid flow, and different scales. By adapting the coupling simulation model to specific cases, the DT framework also can be applied to other multiphase flow imaging techniques. This study provides a paradigm for multiphase flow measurement, extends the limit of ET, and creates an effective avenue for developing artificial intelligence-based quantitative ET techniques.

Results

We first created a three-dimensional Fluid-Electrostatic field Coupling Model (3D-FECM) (see Methods for details of 3D-FECM and Fig.2b) as the digital representation of the testing section of a pilot-scale multiphase flow facility (see Methods for multiphase flow facility details). In the multiphase flow facility, single-phase flows of gas (air) and liquid (white oil) are separately supplied and controlled to generate gas-liquid flows with different volumetric concentrations (see Fig.2a). Similarly, in the virtual space, dynamic flows of gas and liquid are separately regulated to simulate various gas-liquid flows. Figure2cshows examples of typical sequential gas-liquid flows with 0.2 s intervals generated by the 3D-FECM. The pipe is initially filled with liquid. Gas-liquid flows are gradually formed in the horizontal pipe with the gas and liquid injection and then flow through the outlet. Additional representative gas-liquid flows generated from virtual space are presented in Supplementary MoviesS1andS2.

Fig. 2: Three-dimensional coupling simulation of gas-liquid flows.
figure 2

aPhysical gas-liquid flows with different volumetric concentrations present in the testing section of the multiphase flow facility.bThe schematic illustration of the three-dimensional Fluid-Electrostatic field Coupling Model (3D-FECM). Fluid field and electrostatic field are considered to simulate Electrical Capacitance Tomography (ECT) measurements and dynamic gas-liquid flows.cSequential gas-liquid two-phase flows generated by the 3D-FECM.dAn example of the interelectrode capacitance values obtained by the coupling simulation under a stratified flow.

By coupling the fluid and electrostatic fields, the specific electric potential distribution within the virtual ECT sensor is formed, and 66 independent interelectrode capacitances can be obtained during the dynamic simulation process following the ECT measurement principle29(see Fig.2dand Supplementary Fig.S2). To imitate the Signal-Noise Ratio (SNR) of the real-world ECT system, which is around 60 dB30, three levels of additive noise (SNR 60, 50, and 40 dB) are added to the virtual capacitances when reconstructing the cross-section liquid phase distributions in the sensor region. Referring to the actual working conditions of the multiphase flow testing facility, we conduct large-scale virtual experiments and synthesize a simulation dataset consisting of 12,362 samples of gas-liquid flow distributions and corresponding ECT measurements; see Methods for details of virtual multiphase flow data generation. Several examples of gas-liquid flow distributions and related images reconstructed using the conventional algorithm are shown in Supplementary Figs.S34.

We develop a lightweight deep neural network (i.e., Deep Back Projection, DBP) and train the network using the simulation dataset (see Methods for details of DBP). We implement a series of virtual tests (using 50 dB noisy data) to verify the performance of the trained DBP for quantitative gas-liquid flow imaging. We calculate the 2D liquid phase distributions from the 3D liquid phase distributions of the ECT sensing region by averaging voxel-to-voxel along the axial direction of the sensor, and use them as the ground truth (see Fig.3a). The Structural Similarity Index Measure (SSIM)31and the Root Mean Square Error (RMSE)32are adopted as the metrics to evaluate the reconstructed flow images quantitatively. Figure3apresents two representative sets of sequential gas-liquid flows generated by 3D-FECM and corresponding image reconstruction results using DBP when the pipe is initially filled with liquid and gas, respectively. The reconstructed cross-section images from both sets of sequential flows are close to the ground truth, with the SSIM higher than 0.997 and show RMSE lower than 0.014. We also implement virtual gas-liquid transient flow measurement with high temporal resolution (200 frames per second, 0.005 s intervals) to further examine the performance of DBP. Figure3bshows the image reconstruction results for the set of virtual sequential gas-liquid flows in Fig.3a(ii), corresponding dynamic imaging results are presented in Supplementary MoviesS3.

Fig. 3: Quantitative imaging of virtual gas-liquid flows by Deep Back Projection (DBP) with 50 dB Signal-Noise Ratio (SNR).
figure 3

aTwo representative sets of sequential gas-liquid flows generated by three-dimensional Fluid-Electrostatic field Coupling Model (3D-FECM) and corresponding image reconstruction results of DBP. For the sequential gas-liquid flows in (i), the pipe is initially filled with liquid. For the sequential gas-liquid flows in (ii), the pipe is initially filled with gas. 3D dynamic liquid phase distributions in the ECT sensing region can be converted to the 2D volume-averaged liquid phase distributions as the ground truth (see (iii)). The cross-section images reconstructed by DBP for the gas-liquid flows in (iii) are presented in (iv).b虚拟气液transie定量成像nt flow with high temporal resolution (200 frames per second). (v) The authentic liquid phase distributions for evaluating the performance of image reconstruction. (vi) The images reconstructed by DBP for the gas-liquid flows in (v). The cross-section images in (vi) are a set of representative images selected from the continuous reconstruction results. (vii) The Structural Similarity Index Measure (SSIM) and Root Mean Square Error (RMSE) of the DBP results in (vi).

Additionally, we also uniformly deploy eight virtual ECT sensors on the periphery of the pipeline to image the gas-liquid flows along the whole horizontal pipe section (see Supplementary Fig.S6). The goal is to increase the diversity of flow patterns in the virtual dataset. The image reconstruction results in Fig.3and Supplementary Fig.S9show superior quality with the SSIM higher than 0.989 and RMSE lower than 0.024, indicating that the trained DBP can achieve accurate imaging of a wide variety of complex dynamic gas-liquid flows in the virtual space, which is not possible with the conventional ECT approach (see Supplementary Figs.S79for comparison).

We conduct gas-liquid dynamic flow imaging experiments on the pilot-scale multiphase flow facility as a case study to evaluate the performance of our DT framework (see Methods and Supplementary TableS1for detailed experimental setups/test matrix). Supplementary MoviesS4presents gas-liquid flows captured by cameras under three experimental conditions, respectively. Some representative flows for the three experimental conditions are shown in Fig.4a. The pipe is initially filled with liquid. With the gas and liquid injection, stratified gas-liquid flow is gradually presented in the horizontal section and flows through the ECT sensor. When the gas volume flow rate rises from 20.0 to 100.0 m3 h−1and the liquid volume flow rate drops from 5.0 to 2.5 m3 h−1, the liquid volumetric concentration of the gas-liquid flow in the testing section of the pipe decreases notably. Figure4 bshows the continuous imaging results of the DT framework for each experimental condition. All the tomographic images present stratified flow, and the trend of fluid concentration for different conditions is in good agreement with that from the experimental flow observations. The experiment consists of three stable and two intermediate stages (see Fig.4 b(iv)). According to the tomographic data, the liquid volumetric concentration of the gas-liquid flow at each stage is 0.999 ± 0.003, 0.645 ± 0.097, and 0.221 ± 0.113 (mean ± standard deviation), respectively. The gas-liquid flows at intermediate stages contain more abundant dynamic features than the stable stages that are primarily stratified flows. Two sets of time-stacked tomographic images at intermediate stages are selected and presented in Fig.4 b(v) and (vi), respectively. The flow transitions show similarity compared with simulations, with the Liquid Volumetric Concentration fluctuating within 0.988 to 0.730, and 0.735 to 0.306, respectively. We conduct gas-liquid dynamic flow imaging experiments in virtual space, in line with the physical experimental setup, as validation test case to further verify the reliability of 3D-FECM. Gas Volume Fraction (GVF) is one of the critical parameters describing a gas-liquid flow system, and we calculate the mean value of GVF for each working condition by averaging the continuous measurements in the quasi-static stage. Supplementary FigureS11compares the GVF results between the simulation and experiment. We can see that the simulation results agree with the experiment across each working condition, and capture the temporal evolution of the mixture throughout its transient response to varying working conditions.

Fig. 4: Tomographic images of gas-liquid flows in the pilot-scale multiphase flow facility under different experimental conditions.
figure 4

In this experiment, three experimental conditions are selected for testing (see Methods for more details).aFlow profiles captured by the camera. At the initial stage of the experiment, the pipe is filled with liquid (see (i)). The gas and liquid flow into the testing section with volume flow rates of 20.0 and 5.0 m3/h, respectively. The gas-liquid two-phase flow with high liquid volumetric concentration is then formed (see (ii)). When the volume flow rate of the gas rises to 100.0 m3/h and that of the liquid drops to 2.5 m3/h, the gas-liquid flow with low liquid volumetric concentration is formed (see (iii)).bTomographic images obtained from our Digital Twin (DT) framework. (iv) Tomographic images and liquid volumetric concentration variations of the gas-liquid flows ina. Tomographic images in (v) and (vi) show two sets of representative images selected from the time-stacked cross-sectional reconstruction results in (iv).

It is worth pointing out that the ground truth of dynamic multiphase flow profiles in operational flow facilities is in most cases unavailable. As a result, quantitative evaluation of the reconstructed flow images has remained a long-standing yet unsolved challenge. The DT framework presented here addresses this very problem bringing evidence of the capability to visualize and quantify static stratified gas-liquid flows in virtual and physical spaces. We also compare the real-world results with virtual-space results to provide an indicator of the feasibility and performance of the DT framework in the physical world from a quantitative perspective. Figure5a, bshows the imaging results from the virtual and physical spaces, respectively. We observe that the tomographic images of the virtual static stratified flows and real-world flows are very close to actual distributions. The SSIMs of the images for the virtual static flows are higher than 0.969, and those for the real-world static flows are larger than 0.801, indicating that the DT framework can accurately visualize the gas-liquid flows both in virtual and physical spaces. From the continuous imaging results of gas-liquid flows in the physical facility (see Fig.5b), we also see that the SSIM result for each working condition is 0.931 ± 0.023, 0.939 ± 0.030, 0.963 ± 0.019, 0.969 ± 0.016 (mean ± standard deviation), respectively. The relative standard uncertainty of the imaging results is better than 3.19%, indicating superior measurement stability and high repeatability of the DT framework.

Fig. 5: Evaluation of static stratified gas-liquid flow imaging in virtual and physical spaces.
figure 5

aImaging static stratified gas-liquid flows in virtual space by Deep Back Projection (DBP) with 50 dB data. (i) Virtual static gas-liquid flows and corresponding image reconstruction results of DBP. (ii) The Structural Similarity Index Measure (SSIM) and Root Mean Square Error (RMSE) of DBP results in (i).bImaging static stratified gas-liquid flows in physical space using DBP. (iii) Real-world static gas-liquid flows and corresponding image reconstruction results of DBP. (iv) The SSIM of the DBP results in (iii). (v) The standard uncertainty of our Digital Twin framework for imaging the real-world static gas-liquid flows in (iii).

Discussion

In this study, we introduce the DT concept to multiphase flow imaging systems. We propose a DT framework for ET and demonstrate that it can effectively learn the multiphase flow features in virtual space and provide high resolution and accuracy of multiphase flow imaging in physical space. Despite the superiority of our DT framework, several limitations exist due to current technological bottlenecks and simplistic modeling assumptions.

In virtual space, we leverage 3D-FECM to build the digital representation of the physical multiphase flow imaging system. Coupling the fluid and electrical fields allows simultaneous simulation of dynamic multiphase flows and imaging sensors. However, it is noteworthy that the fundamentals and mathematical treatment of multiphase flow modeling are still the focus of active research33. Real-world multiphase flows are among the most complex fluid systems due to the presence of sharp density and velocity gradients across the phases, the strong sensitivity to domain geometrical features and error magnification in the operative conditions. Because of this, achieving a perfect match between the simulation and reality remains an open challenge in the multiphase flow modeling community. To mitigate this issue, instead of focusing on the accuracy of the 3D-FECM model to replicate physical multiphase flows, we resort to generating a variety of gas-liquid flows which carry abundant dynamic features that cover a wide range of complex flow conditions in the flow facility. Another limitation of the virtual model is that, although only the testing section is modeled, it still takes extensive time to generate 3D virtual flow and tomographic measurements for each working condition. This is detrimental to the real-time performance of the DT framework. Model optimization to significantly reduce computational cost and leveraging more powerful computing hardware could be a potential solution.

In physical space, we applied our DT framework to visualize dynamic gas-liquid flows in the laboratory-scale multiphase flow facility. However, it was challenging to obtain the ground truth of dynamic gas-liquid flow profiles that could be used for quantitative performance evaluation. Alternatively, we quantitatively evaluated the imaging results of static stratified flows and compared the dynamic imaging results with those captured by high-speed cameras. Static imaging results reveal that the DT framework can visualize real-world gas-liquid flows with high accuracy and excellent repeatability. Future improvements will be to benchmark the experimental performance by incorporating other advanced imaging techniques, e.g., X-ray tomography and MRI, and to compare DT results with these high-precision imaging techniques. Nevertheless, this will involve multi-sensors integration and multi-signal fusion, and the implementation will be complicated and challenging.

这也是值得注意的,这项工作的重点is the overall DT framework rather than the learning-based algorithm for ECT image reconstruction. We demonstrate that our DT framework can achieve superior performance even when using simple neural architectures like DBP. We also point out that employing dedicated and more specialized neural architectures can potentially lead to a better performance at the cost of a larger training dataset and a more complex training strategy.

In summary, the proposed DT framework for ET utilizes 3D field-coupling simulation, model-based deep learning, and edge computing to enable precise flow profiles imaging with low-cost, nonradioactive, and noninvasive tomography techniques. We demonstrated substantial improvements of DT-powered ET over conventional ET both virtually and in a pilot-scale multiphase flow facility under various gas-liquid flow conditions. Our DT framework can be trained efficiently and flexibly in the virtual space and be readily implemented in the physical space to provide quantitative and stable imaging of gas-liquid flows, representing a step change compared to the state of the art. The framework is in principle generalizable to various imaging techniques, and emerging real-time simulation/data sketching techniques could realistically propel our DT framework towards widespread multiphase flow imaging applications.

Methods

Multiphase flow facility and experiment design

The testing section of a pilot-scale multiphase flow facility (see Supplementary Fig.S1)米ultiphase Flow Engineering Laboratory of the Tsinghua International Graduate School is adopted as a case study. The facility consists of a multiphase flow separator, a gas storage tank, gas and liquid single-phase flow sections, the mixing section, and the control system. In this study, the gas-liquid two-phase flow is considered. The working gas and liquid are air (permittivity 1.0, density 1.3 kg m−3) and white oil (permittivity 2.18, density 879 kg m−3), respectively. The oil is separately supplied and pumped into the flow pipe, then blended with the gas in operation. The mixture is transported through the gas-liquid flow testing section and returned to the separator for circulating utilization. A 12-electrode ECT sensor with a transparent window for visual observation is installed in the horizontal mixing section (see Supplementary Fig.S1c). The testing section has an internal diameter of 50 mm, in which gas-liquid two-phase flows with different volumetric concentrations can be formed by manipulating the air and white oil volume flow rates. During the experiment, the working pressure in the testing section is set to 0.6 MPa and the experimental temperature is about 33 °C. The experimental conditions are listed in Supplementary TableS1, where the volume flow rate of white oil varies from 5.0 to 2.5 m3 h−1, and the volume flow rate of air ranges from 20.0 to 100.0 m3 h−1.

3 d field-coupling simulation

We created a three-dimensional Fluid-Electrostatic field Coupling Model (3D-FECM) to duplicate the testing section of the flow facility. 3D field-coupling simulation was performed using the commercial software COMSOL Multiphysics and Matlab. The model contains the fluid field interface to generate the gas-liquid flow data and an electrostatic field interface to simulate the 12-electrode ECT sensor. Supplementary FigureS2shows the flowchart of the 3D field-coupling simulation. We can simultaneously obtain the dynamic permittivity distribution under various flow conditions and corresponding capacitance measurements from the virtual ECT sensor by coupling the fluid field and the electrostatic field.

流体场的接口,我们采用核纤层蛋白ar two-phase flow, level set method34to track the moving interface between the gas and liquid phases. The gas and liquid phases are air and white oil, respectively. We impose the velocity inlet and pressure outlet boundary conditions to avoid convergence difficulties. We select the suppress backflow to prevent fluid from entering the domain through the outlet boundary. The gas-liquid two-phase flow is set as incompressible flow. In line with the experimental setup, the temperature of the simulation environment is set as 33 °C, the dynamic viscosity of the gas and liquid is set as 1.81E-5 and 0.02 Pa.s, respectively, and the density of the gas and liquid is set as 1.3 and 879 kg m−3, respectively.

We apply the Poisson equation35to determine the electric potential distribution for the electrostatic field interface. We then use the Wiener Upper Bound formula36to evaluate the equivalent permittivity of the gas-liquid mixture. The relative permittivity of the pipe, gas, and liquid is set as 2.6, 1.0, and 2.18, respectively. All the 66 nonredundant interelectrode capacitances are collected for image reconstruction.

虚拟多相流数据集生成

To replicate the real scenarios of the gas-liquid flow testing facility, we initially apply the incompressible Navier-Stokes equations37with gravity to simulate gas-liquid two-phase flows in the horizontal section. The dynamic gas and liquid single-phase flows are separately supplied and controlled. Gas-liquid two-phase flow data with different volumetric concentrations are generated by regulating the inlet velocities perpendicular to the entrance surfaces. The inlet liquid velocity varies from 0.071 to 0.708 m s−1, and the inlet gas velocity varies from 0.236 to 2.362 m s−1. To cover a wide range of volumetric concentrations, two initial conditions are set. One is that the pipe is filled with liquid at the initial stage, and the other is that the pipe is filled with gas at the initial stage. We conduct additional virtual dynamic experiments to generate gas-liquid two-phase flows in the microgravity environment to obtain more abundant flow regimes for the machine learning model training. Supplementary TableS2gives the virtual dynamic experimental matrix. A working condition for the virtual static experiment is also added to generate static stratified gas-liquid flow with the liquid volumetric concentration ranging from 0 to 1. We ran 74 working conditions and collected 12,362 virtual samples containing ECT measurements and phase distributions.

DBP for quantitative flow imaging

We found that the conventional Linear Back Projection (LBP) algorithm29is the most effective in reconstructing dynamic flow profiles than iterative algorithms. We therefore further refine the LBP results with machine learning. DBP is a model-based deep learning algorithm designed to quantitatively image the flow profiles (see Supplementary Fig.S5for the network structure). Here, we consider the commonly used ECT model29, i.e.,

$$\lambda ={Sg}$$
(1)

where\(\lambda\)denotes the normalized capacitance measurement vector;\(S\)is the Jacobian matrix; and\(g\)represents the normalized permittivity distribution within the Region of Interest (ROI).

Reconstruction of the flow distribution with DBP involves two steps. First, the normalized measurement vector\(\lambda\)is mapped into a coarse flow distribution\({g}_{{{{{{{\mathrm{LBP}}}}}}}}\)based on the LBP algorithm29. Then, a modified UNet38is applied to refine the LBP result and produce a more accurate image\({g}_{U}\).

DBP is implemented in Pytorch. The Adam optimizer39is used to update network parameters. The hyperparameters of Adam are set as:\({\beta }_{1}\) = 0.9,\({\beta }_{2}\) = 0.999,\({{{{{\rm{\epsilon }}}}}}\) = 10−9, weight decay = 0. The initial learning rate is 0.001, which decays every 2 epochs with a factor of 1.111. The simulation data is divided into three groups, i.e., the training, validation, and testing sets. The training set includes 10,505 samples (62 different flow conditions at normal time resolution in the dynamic simulation and 89 different flow conditions in the static simulation). The validation set includes 1680 samples (10 different flow conditions at normal time resolution in the dynamic simulation). The testing set includes 1380 samples (one flow condition at normal time resolution, three flow conditions at high time resolution in the dynamic simulation, and nine different flow conditions in the static simulation). All data are augmented by 3 noise levels (i.e., 40, 50, and 60 dB). We select mean square error as the loss function. The batch size and the number of epochs are set to 25 and 80, respectively. The whole training takes about 3 h on three Nvidia Quadro P5000 GPUs. The network with the least validation loss is selected as our final model, which can achieve 0.996 ± 0.012 (mean ± standard deviation) for SSIM, 0.005 ± 0.008 (mean ± standard deviation) for RMSE, and 40.218 ± 1.701 (mean ± standard deviation) for Peak Signal to Noise Ratio (PSNR) on the whole testing set.

AI-powered tomography system

The trained DBP is implemented in the AI-powered electrical tomography system in the physical space. We use ECT to demonstrate the construction of the AI-power tomography system. However, the architecture could be easily extended to other electrical tomography modalities. The AI-powered ECT system is composed of a 32-channel ECT hardware30,40, an edge AI computer (NVIDIA Jetson Nano), and a Visual Tomography (VT) software integrating the trained DBP model for real-time quantitative flow profile reconstruction and key parameter prediction (see Supplementary Fig.S10for the system architecture). The ECT hardware is interfaced with the Jetson Nano through a USB2.0 port. The VT software developed via Python is implemented on Jetson Nano for ECT measurement control, data collection, image reconstruction, and visualization. It also provides an interface to update the trained DBP model dynamically and remotely.